Installation manual

3-21
SIGNAMAX LLC • www.signamax.eu
Downloading System Software from a Server
When downloading runtime code, the new operation code file will overwrite the existing
file.
Versions of the code prior to 1.1.0.10 require the operation code file being transferred to
have the same destination file name as the existing code file for the transfer to succeed.
WebClick System, File Management, Copy Operation. Select “tftp to file” as the file
transfer method, enter the IP address of the TFTP server, set the file type to “opcode,”
enter the file name of the software to download, select a file on the switch to overwrite or
specify a new file name, then click Apply. If you replaced the current firmware used for
startup and want to start using the new operation code, reboot the system via the System/
Reset menu.
Figure 3-9 Copy Firmware
The new file is automatically set as the startup code since the switch only supports the
presence of one firmware file. After the transfer is complete, restart the system for the
new code to take effect.
To delete a file, select System, File, Delete. Select the file name from the given list by
checking the tick box and click Apply. Note that t
he file currently designated as the startup
code cannot be deleted.
Figure 3-10 Deleting Files