Installation manual

4-277
SIGNAMAX LLC • www.signamax.eu
Command Usage
The MEDFastStartCount parameter is part of the timer which ensures that the
LLDP-MED Fast Start mechanism is active for the port. LLDP-MED Fast Start is
critical to the timely startup of LLDP, and therefore integral to the rapid availability of
Emergency Call Service.
Example
lldp notification-interval
This command configures the allowed interval for sending SNMP notifications about
LLDP MIB changes. Use the no form to restore the default setting.
Syntax
lldp notification-interval seconds
no lldp notification-interval
seconds - Specifies the periodic interval at which SNMP notifications are sent.
(Range: 5 - 3600 seconds)
Default Setting
5 seconds
Command Mode
Global Configuration
Command Usage
This parameter only applies to SNMP applications which use data stored in the
LLDP MIB for network monitoring or management.
Information about changes in LLDP neighbors that occur between SNMP
notifications is not transmitted. Only state changes that exist at the time of a
notification are included in the transmission. An SNMP agent should therefore
periodically check the value of lldpStatsRemTableLastChangeTime to detect any
lldpRemTablesChange notification-events missed due to throttling or transmission
loss.
Example
Console(config)#lldp medfaststartcount 6
Console(config)#
Console(config)#lldp notification-interval 30
Console(config)#