Installation manual
4-277
SIGNAMAX LLC • www.signamax.eu
Command Usage
The MEDFastStartCount parameter is part of the timer which ensures that the
LLDP-MED Fast Start mechanism is active for the port. LLDP-MED Fast Start is
critical to the timely startup of LLDP, and therefore integral to the rapid availability of
Emergency Call Service.
Example
lldp notification-interval
This command configures the allowed interval for sending SNMP notifications about
LLDP MIB changes. Use the no form to restore the default setting.
Syntax
lldp notification-interval seconds
no lldp notification-interval
seconds - Specifies the periodic interval at which SNMP notifications are sent.
(Range: 5 - 3600 seconds)
Default Setting
5 seconds
Command Mode
Global Configuration
Command Usage
• This parameter only applies to SNMP applications which use data stored in the
LLDP MIB for network monitoring or management.
• Information about changes in LLDP neighbors that occur between SNMP
notifications is not transmitted. Only state changes that exist at the time of a
notification are included in the transmission. An SNMP agent should therefore
periodically check the value of lldpStatsRemTableLastChangeTime to detect any
lldpRemTablesChange notification-events missed due to throttling or transmission
loss.
Example
Console(config)#lldp medfaststartcount 6
Console(config)#
Console(config)#lldp notification-interval 30
Console(config)#