Installation manual

4-276
SIGNAMAX LLC • www.signamax.eu
lldp holdtime-multiplier
This command configures the time-to-live (TTL) value sent in LLDP advertisements. Use
the no form to restore the default setting.
Syntax
lldp holdtime-multiplier value
no lldp holdtime-multiplier
value - Calculates the TTL in seconds based on
(holdtime-multiplier * refresh-interval)
65536
(Range: 2 - 10)
Default Setting
Holdtime multiplier: 4
TTL: 4*30 = 120 seconds
Command Mode
Global Configuration
Command Usage
The time-to-live tells the receiving LLDP agent how long to retain all information
pertaining to the sending LLDP agent if it does not transmit updates in a timely
manner.
Example
lldp medFastStartCount
This command specifies the amount of MED Fast Start LLDPDUs to transmit during the
activation process of the LLDP-MED Fast Start mechanism.
Syntax
lldp medfaststartcount packets
seconds - Amount of packets. (Range: 1-10 packets; Default: 4 packets)
Default Setting
4 packets
Command Mode
Global Configuration
Console(config)#lldp holdtime-multiplier 10
Console(config)#