Installation manual
4-220
SIGNAMAX LLC • www.signamax.eu
Default Setting
2 seconds
Command Mode
Global Configuration
Command Usage
This command sets the time interval (in seconds) at which the root device transmits
a configuration message.
Example
Related Commands
spanning-tree forward-time (4-219)
spanning-tree max-age (4-220)
spanning-tree max-age
This command configures the spanning tree bridge maximum age globally for this switch.
Use the no form to restore the default.
Syntax
spanning-tree max-age seconds
no spanning-tree max-age
seconds - Time in seconds. (Range: 6-40 seconds)
The minimum value is the higher of 6 or [2 x (hello-time + 1)].
The maximum value is the lower of 40 or [2 x (forward-time - 1)].
Default Setting
20 seconds
Command Mode
Global Configuration
Command Usage
This command sets the maximum time (in seconds) a device can wait without
receiving a configuration message before attempting to reconfigure. All device ports
(except for designated ports) should receive configuration messages at regular
intervals. Any port that ages out STA information (provided in the last configuration
message) becomes the designated port for the attached LAN. If it is a root port, a
new root port is selected from among the device ports attached to the network.
Example
Console(config)#spanning-tree hello-time 5
Console(config)#
Console(config)#spanning-tree max-age 40
Console(config)#