Installation manual

4-157
SIGNAMAX LLC • www.signamax.eu
web-auth login-attempts
This command defines the limit for failed web authentication login attempts. After the limit
is reached, the switch refuses further login attempts until the quiet time expires. Use the
no form to restore the default.
Syntax
web-auth login-attempts count
no web-auth login-attempts
count - The limit of allowed failed login attempts. (Range: 1-3)
Default Setting
3 login attempts
Command Mode
Global Configuration
Example
web-auth quiet-period
This command defines the amount of time a host must wait after exceeding the limit for
failed login attempts, before it may attempt web authentication again. Use the no form to
restore the default.
Syntax
web-auth quiet-period time
no web-auth quiet period
time - The amount of time the host must wait before attempting authentication
again. (Range: 1-180 seconds)
Default Setting
60 seconds
Command Mode
Global Configuration
show web-auth Displays global web authentication parameters PE 4-160
show web-auth interface Displays interface-specific web authentication parameters
and statistics
PE 4-161
show web-auth summary Displays a summary of web authentication port parameters
and statistics
PE 4-159
Console(config)#web-auth login-attempts 2
Console(config)#
Table 4-43 Web Authentication (Continued)