Installation manual
4-94
SIGNAMAX LLC • www.signamax.eu
• Note that the authentication, link-up and link-down messages are legacy traps and
must therefore be enabled in conjunction with the
snmp-server enable traps
command (page 4-89).
Example
show snmp group
Four default groups are provided – SNMPv1 read-only access and read/write access, and
SNMPv2c read-only access and read/write access.
Command Mode
Privileged Exec
Example
Console(config)#snmp-server group r&d v3 auth write daily
Console(config)#
Console#show snmp group
Group Name: r&d
Security Model: v3
Read View: defaultview
Write View: daily
Notify View: none
Storage Type: permanent
Row Status: active
Group Name: public
Security Model: v1
Read View: defaultview
Write View: none
Notify View: none
Storage Type: volatile
Row Status: active
Group Name: public
Security Model: v2c
Read View: defaultview
Write View: none
Notify View: none
Storage Type: volatile
Row Status: active
Group Name: private
Security Model: v1
Read View: defaultview
Write View: defaultview
Notify View: none
Storage Type: volatile
Row Status: active