Installation manual
4-58
SIGNAMAX LLC • www.signamax.eu
Command Usage
This command shows the system and event messages stored in memory, including
the time stamp, message level (page 4-52), program module, function, and event
number.
Example
The following example shows sample messages stored in RAM.
SMTP Alert Commands
These commands configure SMTP event handling, and forwarding of alert messages to
the specified SMTP servers and email recipients.
Console#show log ram
[5] 00:01:06 2001-01-01
"STA root change notification."
level: 6, module: 6, function: 1, and event no.: 1
[4] 00:01:00 2001-01-01
"STA root change notification."
level: 6, module: 6, function: 1, and event no.: 1
[3] 00:00:54 2001-01-01
"STA root change notification."
level: 6, module: 6, function: 1, and event no.: 1
[2] 00:00:50 2001-01-01
"STA topology change notification."
level: 6, module: 6, function: 1, and event no.: 1
[1] 00:00:48 2001-01-01
"VLAN 1 link-up notification."
level: 6, module: 6, function: 1, and event no.: 1
Console#
Table 4-18 SMTP Alert Commands
Command Function Mode Page
logging sendmail host SMTP servers to receive alert messages GC 4-59
logging sendmail level Severity threshold used to trigger alert messages GC 4-59
logging sendmail
source-email
Email address used for “From” field of alert messages GC 4-60
logging sendmail
destination-email
Email recipients of alert messages GC 4-60
logging sendmail Enables SMTP event handling GC 4-61
show logging sendmail Displays SMTP event handler settings NE, PE 4-61