Installation manual
4-21
SIGNAMAX LLC • www.signamax.eu
banner configure company
This command is used to configure company information displayed in the banner. Use the
no form to restore the default setting.
Syntax
banner configure company name
no banner configure company
name - The name of the company. (Maximum length: 32 characters)
Default Setting
None
Command Mode
Global Configuration
Command Usage
Input strings cannot contain spaces. The banner configure company command
interprets spaces as data input boundaries. The use of underscores ( _ ) or other
unobtrusive non-letter characters is suggested for situations where white space is
necessary for clarity.
Example
banner configure dc-power-info
This command is use to configure DC power information displayed in the banner. Use the
no form to restore the default setting.
Syntax
banner configure dc-power-info floor floor-id row row-id rack rack-id
electrical-circuit ec-id
no banner configure dc-power-info [floor | row | rack | electrical-circuit]
• floor-id - The floor number.
• row-id - The row number.
• rack-id - The rack number.
• ec-id - The electrical circuit ID.
Maximum length of each parameter: 32 characters
Default Setting
None
Command Mode
Global Configuration
Console(config)#banner configure company SIGNAMAX_Corporation
Console(config)#