Web – Click IGMP Snooping, IGMP Filter/Throttling Port Configuration or IGMP Filter/
Throttling Trunk Configuration. Select a profile to assign to an interface, then set the
throttling number and action. Click Apply.
Figure 3-144 IGMP Filter and Throttling Port Configuration
CLI – This example assigns IGMP profile number 19 to port 1, and then sets the throttling
number and action. The current IGMP filtering and throttling settings for the interface are
then displayed.
Console(config)#interface ethernet 1/1 4-186
Console(config-if)#ip igmp filter 19 4-326
Console(config-if)#ip igmp max-groups 64 4-327
Console(config-if)#ip igmp max-groups action deny 4-327
Console(config-if)#end
Console#show ip igmp filter interface ethernet 1/1 4-328
Information of Eth 1/1
IGMP Profile 19
permit
range 239.1.2.3 239.1.2.3
range 239.2.3.1 239.2.3.200
Console#show ip igmp throttle interface ethernet 1/1 4-329
Information of Eth 1/1
status : TRUE
action : deny
max multicast groups : 64
current multicast groups: 0