Signamax Connectivity System 065-9066 Signamax Connectivity Systems GSM GATEWAY 065Model: 065 -9066 User Manual Version: 1.01 1.01 – www.signamax-us.com www.signamax-eu.
Signamax Connectivity System 065-9066 TABLE OF CONTENTS PREFACES 4 0.1 ABOUT THIS MANUAL 4 0.2 COPYRIGHT DECLARATIONS 4 0.3 TRADEMARKS 4 0.4 SAFETY INSTRUCTIONS 4 0.5 WARRANTY 5 INTRODUCE INTRODUCE 5 1.1 OVERVIEW 5 1.2 ACRONYMS TABLE 6 1.3 INTRODUCTION 6 1.4 FRONT PANEL LED INDICATORS & REAR PANELS 7 1.4.1 OUTLOOK OF GATEWAY 7 1.4.2 FRONT PANEL LED AND CONTAINER DESCRIPTIONS 7 1.4.3 REAR PANEL DESCRIPTIONS 8 1.
Signamax Connectivity System 065-9066 3.1.2 PSTN DIALPLAN 21 3.1.3 GSM DIALPLAN 21 3.1.4 SMS SETTING 22 ADVANCED SETUP 23 4.1 NETWORK CONFIGURATION 24 4.1.1 WAN PORT TYPE SETUP 24 4.1.2 4.1.2 DYNAMIC YNAMIC DNS 26 4.1.3 4.1.3 NETWORK MANAGEMENT 27 4.2 VOIP SETUP 27 4.2.1 H.323 H.323 SETUP 27 4.2.2 SIP SETUP 33 4.2.3 DIRECT CALL (PEER TO PEER) SETUP 37 4.2.4 OTHER VOIP SETTING 40 4.3 4.3 SYSTEM ADMINISTRATOR 41 4.3 4.3.1 SAVE CONFIGURATION AND REBOOT 42 4.3 4.3.
Signamax Connectivity System 065-9066 PREFACES 0.1 About This Manual This manual is designed to assist users in using GSM Gateway. Information in this document has been carefully checked for accuracy; however, no guarantee is given as to the correctness of the contents. The information contained in this document is subject to change without notice. 0.2 Copyright Declarations Copyright 2007 Telephony Corporation. All rights reserved. This publication contains information that is protected by copyright.
Signamax Connectivity System 065-9066 0.5 Warranty We warrant to the original end user (purchaser) that the GSM gateway will be free from any defects in workmanship or materials for a period of one (1) years from the date of purchase from the dealer. Please keep your purchase receipt in a safe place as it serves as proof of date of purchase.
Signamax Connectivity System 065-9066 The 065-9066 Quad-Band GSM over VoIP gateway has been designed for user to make calls and receive calls from a cellular phone via the internet using VoIP (SIP/H.323). 1.
Signamax Connectivity System 065-9066 1.4 1.4 Front Panel LED Indicators & Rear Panels 1.4.1 Outlook of Gateway Front Rear 1.4.
Signamax Connectivity System GSM SMS 065-9066 On GSM Network is found and working properly Flashing Searching GSM Network ON Short message waiting Indicator Flashing Sending short message 1.4.3 Rear Panel Descriptions Port Description Phone Phone port can be connected to analog telephone sets or Trunk Line of PBX Line Can be Connected to PBX or CO line with RJ-11 analog line. PSTN not FXO port, can’t connect PSTN to VoIP,.
Signamax Connectivity System 065-9066 1.
Signamax Connectivity System 065-9066 IP Specifications ‧H.323 v2/v3/v4 and SIP (RFC 3261), SDP (RFC 2327), Symmetric RTP, STUN (RFC3489), ENUM (RFC 2916), RTP Payload for DTMF Digits (RFC2833), Outbound Proxy Support. ‧Voice Codec: G.711(A-law /µ-law), G.729 AB, G.723 (6.3 Kbps / 5.3Kbps) ‧WAN: Support PPPoE client, DHCP client, Fix IP Address, DDNS client ‧Support MWI (Message Waiting Indicator) by SIP Notify.
Signamax Connectivity System 065-9066 Appurtenances: CD ROM CD Include in all product user manual and datasheet. RJRJ-45 cable Internet cable RJ-45 connect to NIC/Gateway/Router Antenna This Antenna frequency is 900MHz/1800,1900Mhz for automobile. Power supply Power Supply,input:100-240V output:+12V (Europe/UK/US) 2.2 Installation 1. Install Gateway 1 Connect the 12V DC IN to the power outlet with power adaptor. 2 Connect Line to PSTN Line.
Signamax Connectivity System 065-9066 2. Change the IP address to 192.168.1.2(2~254 is ok) 3. Change the subnet mask to 255.255.255.0 4. Change the gateway and the preferred DNS server to 192.168.1.1 IP configuration configurations rations above please refer to page 15 3. After Network Configuration is done. Connecting to an External Ethernet Hub or Switch: 1 Connect the Ethernet cable (with RJ-45 connector) to WAN port.
Signamax Connectivity System 065-9066 The hardware installation is now complete. The following sections will guide you through setting up your management PC and connecting to the Web User Interface. 2.3 Setup There are 2 way to setting gateway - Web User Interface, Telnet 2.3.1 Factory Default setting WAN Port IP address : 192.168.1.
Signamax Connectivity System 065-9066 (Your particular system will be different from the screen shown here.) Check that you have an Ethernet network card installed. If not, refer to the card manufacturer’s documentation and install the card and drivers. If your card is installed, 1. Click the Add button. The Select Network Component Type dialog box will open. The box will show four options: Client, Adapter, Protocol, and Service. 2. Select Protocol and click the Add button.
Signamax Connectivity System 065-9066 Configuring the TCP/IP Protocol 1. On the Network dialog box Configuration card, select TCP/IP and then click Properties.” The TCP/IP Properties dialog box will open. 2. On the IP Address tab, Change the IP address to 192.168.1 192.168.1.2(2~254 is ok) the subnet mask to 255.255.255.0, 255.255.255.0 the gateway and the preferred DNS server to 192.168.1 192.168.1.1 5. click OK. A dialog box will pop up asking you to restart the PC. Click Yes”.
Signamax Connectivity System 065-9066 2.3.2 Telnet Connect WAN port to Internet or PC and gateway at the same subnet. you can use telnet remote to configure your gateway. 1. Connect Gateway online (Wan) 2. Remote Gateway by Telnet. If telnet successful, you will see Login display. (For Example: telnet 192.168.1.1) 3. Input Password (Gateway Access password, Default: admin), If login successful, you will enter the welcome display. 4.
Signamax Connectivity System 065-9066 3.Network Management 4.VoIP Basic 5.Dialing Plan 6.VoIP Advance Setting 7.Hot Line Setting 8.Port Status 9.Busy Tone Learning a. Show DNS mapping [1]Advanced Setup 1.Change WAN Type to DHCP ……1.WAN Setting 2.Change WAN Type to Fixed IP 3.Change PPPoE Username 4.Change PPPoE Password [1]Advanced Setup 1.Change DDNS username ……2.NS/Dynamic DNS 2.Change DDNS password Setting 3.Change DDNS domain name 4.Change DNS server IP 5.Enable/Disable Get DNS Server IP 6.
Signamax Connectivity System 065-9066 2.Change Codec 3.Enable/Disable UK PSTN Tone Detection? 4.Enable/Disable Dial Complete Tone 5.Dial Termination Key Setting 6.FXS Parameters Setting 1.Change FXS Impedance 2.Change Phone In Volume 3.Change Phone Out Volume 4.Flash Detection 5.Ring Frequency 6.FXS Battery reversal generation (3)Network Advance 1.Disable Smart QOS 2.Bandwidth Control 3.G.723 Bandwidth 4.G.729 Bandwidth 5.Set IP TOS [1]Advanced Setup 1.Change Port1 Hot Line Number ……7.
Signamax Connectivity System 065-9066 GSM SETUP 3.1 GSM SETUP GSM Parameter GSM Parameter allows you to modify the option of GSM network. PSTN Dailplan Users could apply any dial policy by setting Dial Plan to route the Calls to PSTN GSM Dialplan Users could apply any dial policy by setting Dial Plan to route the Calls to GSM Network. SMS setting www.signamax-us.com The Option is used to send short message to mobile phones www.signamax-eu.
Signamax Connectivity System 065-9066 3.1.1 GSM Parameter PIN Code Protection: Protection: Enable PIN Code protection. Failsafe Mechanism: Mechanism: If enable, when GSM Network is failed or GSM Gateway is out of the GSM service range. ALL the calls from FXS will route to PSTN port. Baby Call: Call: When the calls come to FXS port, it will call hot line number to GSM automatically. Follow ME: ME: When the calls come to PSTN, it will call hot line number to GSM automatically.
Signamax Connectivity System 065-9066 PSTN Route Numbers: Numbers: The numbers which are filled in the form will go through the PSTN line unconditionally. You can use x as wild card. For examples: Emergent calls, like 911 Zone Numbers, like 02x (the phone numbers start with 02) 3.1.3 GSM Dialplan GSM Numbers: The numbers which are filled in the form will go through GSM Network unconditionally. You can use x as wild card.
Signamax Connectivity System 065-9066 3.1.4 SMS Setting Sending Number: Number: The telephone number which an short message is sent to. SMS Content: Content: The SMS Content will be sent to the preset telephone number. If the SMS text is blank,an empty SMS is sent. The Maximum capacity is 40 characters. Advanced Configuration www.signamax-us.com www.signamax-eu.
Signamax Connectivity System 065-9066 Network Setup WAN Setting Sets/changes the WAN port Type like “Fixed IP”, “DHCP Client” or ”PPPoE”. Dynamic DNS Dynamitic DNS allows you to provide Internet users with a domain name to access your server. Network Parameters Network Parameter allows you to modify the access port of gateway.
Signamax Connectivity System 065-9066 Management Label Save Configuration You can save configuration and restart the gateway with the default configuration or with the current running configuration. Access Control Users can Sets/changes the administrator password.. Set to Default You can restart the gateway with the default configuration. System Information Display Software version, WAN Type, VoIP Status, VoIP Codec, Phone Interface and System Tim.
Signamax Connectivity System 065-9066 IP Address: check with your ISP provider Subnet mask: check with your ISP provider Default Gateway: check with your ISP provider PPPoE for ADSL Some ISPs provide DSL-based service and use PPPoE to establish communication link with end-users. If you are connected to the Internet through a DSL line, check with your ISP to see if they use PPPoE. If they do, you need to select this item.
Signamax Connectivity System 065-9066 IP Address: If you are connected to the Internet through a Cable modem line then a dynamic IP address will be assigned. (Note : WAN port display the IP address, Subnet Mask and Default gateway IP address if DHCP client is successful) 4.1.2 Dynamic DNS DDNS is a service that maps Internet domain names to IP addresses. DDNS serves a similar purpose to DNS: DDNS allows anyone hosting a Web or FTP server to advertise a public name to prospective users.
Signamax Connectivity System 065-9066 4.1.3 Network Management Network Management,, access port configuration allows you to modify the HTTP port or TELNET port for accessing VoIP gateway (Default Parameter : HTTP Port is 80 ; TELNET Port is 23) Http Server Port: Input you want to change Web access port (Default is 80) Telnet Server Port: Input you want to change telnet access port (Default is 23) 4.2 VoIP Setup GSM Gateway support 2 VoIP protocol - H.323 / SIP, you can register to H.
Signamax Connectivity System 065-9066 1. Configure the numbering with FXS / GSM ports. FXS Number: The representation number is the phone number of the telephone that is connected to FXS port. GSM Number: The representation number is the phone number of SIM CARD (Port number is in comparison with gateway port number. White Port socket is “GSM” port, Black Port socket is “FXS” port.) 2. Configure the ANI (Answer Number Indication) / Caller ID of the FXS/GSM ports.
Signamax Connectivity System 065-9066 H.323 Parameters Label Sets the unique name of this Gateway, that is communicated as part of H.323 ID H.323 messaging.. There are two gatekeeper address fields, one is primary, the other Primary Gatekeeper secondary. If this gateway does not want to register to any gatekeeper, IP Address just set value 0 to the primary gatekeeper address. If the primary gatekeeper address is not 0, the gateway will register to the primary gatekeeper.
Signamax Connectivity System 065-9066 [Advance Setting] Item Description DTMF Relay for H.323: After the VoIP call is connected, when you dial a digit, this digit is sent to the other side by DTMF tone. There are two methods of sending the DTMF tone. The first is “in band”, that is, sending the DTMF tone in the voice packet. The other is “out band”, that is, sending the DTMF tone as a signal. Sending DTMF tone as a signal could tolerate more packet loss caused by the network.
Signamax Connectivity System 065-9066 selection is enabled, the H.323 signaling part is connected during the ringing period. The benefit of this situation is that the remote side could hear the status of the specific port. That is, the remote side will hear ring back tone if the Gateway is really ringing the phone set. If the phone set is busy, the remote side will hear busy tone. The disadvantage of this situation is that the H.323 connected time is not the real voice call connected time.
Signamax Connectivity System Voice Codec option: 065-9066 The Codec is used to compress the voice signal into data packets. Each Codec has different bandwidth requirement. There are four kinds of Codec, G.723, G.729AB, G.711_u and G.711_A. The default value is G.723. Dial Complete Tone: When you use the VoIP call, you will heard “DuDu” voice that is dial complete tone. If you don’t want to heard that tone , you can disable it.(default is enable).
Signamax Connectivity System IP TOS: TOS: 065-9066 Some Router support TOS(Type of Service), when you enable the TOS function, the router will process those packets firstly.(default is disable) 4.2.2 SIP Setup Gateway SIP support SIP(RFC3261), SDP(RFC2327), RFC2833, STUN(RFC3489), Symmetric RTP, outbound proxy, ENUM(RFC2916),and RTP/RTCP.SIP NAT pass through Function can support 80% NAT/Firewall that you don’t setting DMZ/Virtual server in router or Firewall. 1. Select “SIP Protocol” 2.
Signamax Connectivity System 065-9066 SIP Proxy Server Label 1. Enter the SIP service IP address or domain name in this field (the SIP Proxy Server Setting domain name that comes after the @ symbol i n a full SIP URI). 2. Use Net2Phone Service Provider SIP Domain 1. Enter the SIP realm in this field This field sets how long an entry remains registered with the SIP Register Interval Setting register server. The register server can use a different time period.
Signamax Connectivity System 065-9066 SIP VoIP Advanced Configuration There are many SIP VoIP, Codec and other more detail Setting, you can set in “Advance Advance Setting”. Setting For SIP and H.323, there are a little different in advance setting. There are 3 different parts to setting about VoIP, Telephone and network. [VoIP Advance] Item Description DTMF Relay for SIP: After the VoIP call is connected, when you dial a digit, this digit is sent to the other side by DTMF tone.
Signamax Connectivity System 065-9066 [Telephone Advance] Item Description Silence Compression: If this function is enabled, when silence is occurred for a (VAD) period of time, no data will be sent across the network during this period in order to save bandwidth. (If you use Asterisk, please disable Silence Compression, it maybe make you call disconnect.) Voice Codec option: The Codec is used to compress the voice signal into data packets. Each Codec has different bandwidth requirement.
Signamax Connectivity System Ring Frequency: Frequency: 065-9066 You can configure how long the Ring Frequency do you want to use. DTMF tone power: Sometimes you input DTMF, but no request. You can adjust this function, range from -6db to +6db. [Network Advance] Item Description SmartSmart-QoS: If this function is enabled, when VoIP call is occurred, the other data will be automatically reduced traffic which across the internet in order to guarantee the voice bandwidth.
Signamax Connectivity System 065-9066 1. Outgoing Dial Plan: Peer-to-Peer Call Mode: Effective Registering to H.323 Gatekeeper (SIP Proxy Server) Mode: Effective 2. Incoming Dial Plan: Peer-to-Peer Call Mode: Effective Registering to H.323 Gatekeeper (SIP Proxy Server) Mode: The leading number would register to H.323 Gatekeeper (SIP Proxy Server) When you use direct call, you must setting your VoIP protocol firstly. Use direct call, you should setting the same protocol both of UA.
Signamax Connectivity System 065-9066 Example1: Normally Dial 1.001x 1.001x leading call out, call to Destination Destination IP address: 211.22.3.14 2.002x 2.002x leading call out, call to Destination Domain Name: h.323.gw.net Example2: Speed Dial 1. If user dial “401”, Gateway automatically dial “1334588712” to Destination IP address: 211.22.3.14 2. If user dial “402”, “402”, Gateway Gateway automatically dial “22123456 “2212345612” 2212345612” to Destination IP address: 211.21.2.
Signamax Connectivity System 065-9066 “Destination Tele port” is “Tel-port”; this is for local dial plan setting phone number. 4.2.4 Other VoIP Setting Hot Line: Line: You can setting hot line. when the call incoming the hot line port, it will call hot line number automatically. The hot line call the number via VoIP, so you setting the hot line number must VoIP number. Usually, you want to incoming GSM calls transfer to FXS, you only setting the GSM hot line to FXS number.
Signamax Connectivity System 065-9066 For example, if I have a gateway , and It is registered a proxy server, I don’t setting any others (Hot Line or dialing plan.). when I make a VoIP call, gateway will check Proxy server. Now,, I setting 1~2 dialing plan, and registered proxy server. When I call, gateway will check the dialing plan first, then find the proxy server. And so on…..
Signamax Connectivity System 065-9066 4.3.1 Save Configuration and Reboot Click “Save Configuration and Reboot” to save configuration and begin to restart. (When you set done, select “Reboot” option will auto save and reboot!) 4.3.2 Access Control Changing the Administrator Password For security reasons, we strongly recommend that you set an administrator. password for the router. On first setup the router requires no password.
Signamax Connectivity System 065-9066 If you want to reboot the router using factory default configuration, Apply” configuration click “Apply Apply then reset the router’ s settings to default values. 4.3.4 System Information Display Function Click System Information Display to open the Online Status page. In the example, on the following page, both PPPoE connection is up on the WAN interface, H323 Status, MAC address, Register Status, etc…. 4.3.
Signamax Connectivity System 065-9066 4.3.6 Syslog Setting Function Use Syslog server to record your Gateway log file. you can setting you syslog server IP address for this function. Syslog information include the CDR source! 4.3.7 Capture Packets Function Use “Capturer Packets” to record Gateway packets. You can start and stop the capture then save the file to PC Use the Ethereal Tool (www.ethereal.com) to analyze the packets.
Signamax Connectivity System 065-9066 FTP upgrade Requirement and Process 1. Environment Requirement PC with FTP Server (Server-U software, 3CDaemon,..) PC or Notebook witch connected to WAN port of Gateway. Put the image (firmware) named “v100.xxx” at the assigned folder in FTP Server. ( for example: “v100.270” is version 2.7.0 ) Note: Our company FTP server, you can use it to upgrade Free FTP server : 61.218.109.
Signamax Connectivity System 065-9066 Please input IP address of FTP server like as : 61.218.109.83 Username : share Passswd : 19730809 Imagename: s400.271 Upgrade (y/n) : y , then will write the firmware to flash. (In different module or firmware , maybe have different change) After writing flash, Please reboot the Gateway. If the new firmware (image) was most different with the previous version, please push the hardware reset bottom to set to default.
Signamax Connectivity System 065-9066 Appendix A FAQ List 1. What is the default administrator password to login to the gateway? A: By default, your default username is “admin”, default password is “admin” to login to the router. For security, you should modify the password to protect your gateway against hacker attacks. 2. I forgot the administrator password. What should I do? A: Press the Reset button on the rear panel for over 5 seconds to reset all settings to default values.
Signamax Connectivity System 065-9066 configuration. B SIP Setting VoIP Buster VoIPBuster Service Using VoIP Gateway The Signamax GSM Gateway VoIP Gateway can register to VoIPBuster (http://www.voipbuster.com) VoIP service by SIP protocol and also can call SIP calls by VoIPbuster (http://www.voipbuster.com) service. Gateway Setting 1. VoIPBuster SIP Proxy Server : sip.voipbuster.com / 5060 2. VoIPBuster STUN Server: stun.voipbuster.com / 5060 3.
Signamax Connectivity System 065-9066 VoIPBuster Provides Free Land Line (Fixed Line) Calls C Sip Speeds call Speed Call Concept: Cut your phone number down to fewer digit dialing! Life is moving fast - you've got to dial fast. Now you can with Speed Dial. Dial the people you call most with just dialing fewer digits instead of dialing the full phone number. SIP Register Mode Example: Gateway Gateway registers to sip proxy server: service.sip.
Signamax Connectivity System 065-9066 Example 2: you want to dial 8686-1111222333 instead of 810810-8686-1111222333 The destination IP address address is the domain name of sip proxy server Example 3: you want to dial 999 instead of 810810-86111222333 The destination IP address is the domain domain name of sip proxy serve 1. Choose “VoIP Basic”. Login in web interface, and in ”Advance Setting”. www.signamax-us.com www.signamax-eu.
Signamax Connectivity System 065-9066 2. Select you wan to use protocol (SIP/H.323). 3. Input you want to use call number. Setp_2:Setting Dialing plan For Gateway_1 Setting 1. Choose “Dialing plan” and Setting Outgoing Dial plan. 2. Setting dial plan just like picture for demo.”20x” the “x” mean wild card , it can be one of “0~9” number. And length “3~3”, when you input 3 number and the call will be made. Destination is the Gateway_2 IP address. www.signamax-us.com www.signamax-eu.
Signamax Connectivity System 065-9066 For Gateway_2 Setting 1. choose “Dialing “Dialing plan” and Setting Outgoing Dial plan. 2. Setting dial plan just like picture for demo.”10x” the “x” mean wild card , it can be one of “0~9” number. And length “3~3”, when you input 3 number and the call will be made. Destination is the Gateway_1 IP address. address. Step_3:make call each other 1.When you setting 2 gateway done, you can make call by each other.
Signamax Connectivity System www.signamax-us.com 065-9066 www.signamax-eu.
Signamax Connectivity System www.signamax-us.com 065-9066 www.signamax-eu.