Specifications

B
MEDIA
CONVERTER
SYSTEM
TM
www.signamax.eu
B22
The Signamax™ 065-1480 18-Bay Managed Media Converter Rack Mount Chassis provides full SNMP
management capabilities for mission-critical installations. The 065-1480 provides 18 bays of space for all
065-14xx series Signamax managed media converters in a standard 2U high enclosure. It also includes the
065-1481 Management Module, which communicates with the Signamax 065-14xx series media converters
on the chassis’ backplane. It provides full status information on the individual media converter’s ports
and allows the advanced management capabilities of the 065-14xx series managed media converters to
be switched on or off remotely and individually. Diagnostic testing from a centralized location avoids
unnecessary technician dispatch. Alarm traps can be sent to up to five remote IP addresses simultaneously,
allowing integration within a variety of Network Management Systems. In-band and out-of-band
management are supported by local and remote Telnet console Command Line Interface (CLI), a web
browser-based Graphical User Interface (GUI), and a menu-driven interface.
Two fully redundant, load-sharing power supplies are standard, to ensure continued availability of
the media converters in the event of a power supply failure. Either power supply is hot-swappable and can
be taken off-line and removed from the unit while the media converters are operating; the media converters
themselves are also hot-swappable. The 065-1480 also ships standard with three fully redundant, load-
sharing cooling fans to ensure reliable operation.
PART NO. DESCRIPTION
065-1480 18-Bay Rack Mount Managed Media Converter Chassis System; includes 065-1481 SNMP
Management Module, 2 Redundant AC Power Supplies, & 3 Fan Cooling Assemblies
065-1480DC 18-Bay Rack Mount Media Converter Chassis System; includes 065-1481 SNMP Management Module,
2 Redundant -48 V DC Power Supplies, & 3 Fan Cooling Assemblies
065-1481 Spare SNMP Management Module
AC-1480 Spare Redundant AC Power Supply for 18-Bay Chassis
DC-1480 Spare Redundant -48 V DC Power Supply For 18-Bay Chassis
1480FAN Spare Individual Fan Assembly For 18-Bay Chassis
18-Bay Rack Mount Managed Media Converter Chassis System
065-1480 Chassis
CAPACITY
Eighteen bays for up to eighteen 065-14xx
Media Converters
CONSTRUCTION
SECC zinc-coated steel
COOLING
One 42.5 cfm rear-mounted fan, plus one fan for
each of the two redundant power supplies.
LEDs
Power (2x): Power supply on-line
FAN (3x): Fan status
DIMENSIONS (W x D x H)
440 x 276 x 90 mm
(17.3 x 10.9 x 3.5")
2 standard rack units
WEIGHT
Approximately 13.5 kg, fully loaded
POWER SUPPLIES—LOAD SHARING
AND HOT-SWAPPABLE
(2 supplied as standard equipment)
Input:
model 065-1480: 90 – 240 Volts AC,
47 – 63 Hz
model 065-1480DC: -48 Volts DC
Output:
Normal +12 Volts DC (Min. +11.88 Volts,
max. +12.12 Volts, 7.0 Amps)
Total Regulation:
+/-1.0%, Rip. 120 mV, Load 1.0%, Line 0.5%
Overload Protection:
All outputs protected against short circuit
conditions; automatic recovery
Excess Voltage Protection:
Output level exceeding 13.2 Volts causes
shutdown; automatic recovery
Temperature:
Operating: 0° – 40°C
Storage: -25° – 70°C
EMI: FCC Part 15 Class A, CE Class A
Safety: UL 1950 Listed
065-1481 Management Module
PROTOCOLS SUPPORTED
TCP, UDP, ICMP, IP, ARP
SERVICE
HTTP, Telnet, SNMP, TFTP
PORTS
DB-9 Serial Data (x1),
RJ45 10/100BaseT/TX (x1)
LEDs
Power, System, Alert, 10/100 speed, Link/ACT
MIB SUPPORTED
MIB II, RMON
PHYSICAL CHARACTERISTICS
Storage temp.: -40° – 80°C
Operating temp.: 0° – 50°C
Maximum altilude: 10,000 ft.
Dimensions (L x W x H):
171.5 x 69 x 21.5 mm
Weight: 115 grams
EMI: FCC Part 15 Class A, CE Class A
SPECIFICATIONS
18-Bay Rack Mount Managed Media Converter
Chassis System
Model 065-1480