2-1-3-1. Configuring Management Agent of the 065-7931 16-Port
10/100/1000BaseT/TX WebSmart Switch through an Ethernet Port
There are two ways to configure and monitor the switch through the switch’s
Ethernet port: by using a Web browser and by using an SNMP manager. The user
interface for the SNMP manager is NMS dependent and is not covered here; the
Web-based UI for the switch is a highly user-friendly interface.
Managing the 065-7931 16-Port 10/100/1000BaseT/TX WebSmart Switch
through an Ethernet Port
Before the user communicates with the switch, they must first finish the
configuration of the IP address or know the current IP address of the switch. Then,
the user must follow the procedures listed below.
1. Set up a physical path between the configured the switch and a PC
by a qualified UTP Cat. 5 cable with RJ-45 connector.
Note: If PC directly connects to the switch, you have to setup the
same subnet mask between them. However, the subnet mask may
be different for the PC in the remote site. Please refer to Fig. 2-6
regarding the 065-7931 16-Port 10/100/1000BaseT/TX WebSmart
Switch default IP address information.
2. Run the web browser and follow the menu. Please refer to Chapter
4.
065-7931 16-port 10/100/1000BaseT/TX WebSmart Switch
Default IP Setting:
IP = 192.168.1.1
Subnet Mask = 255.255.255.0
Default Gateway = 192.168.1.254
Assign a reasonable IP address,
For example:
IP = 192.168.1.100
Subnet Mask = 255.255.255.0
Default Gateway = 192.168.1.254
Fi
g
. 2-6
Ethernet LAN