System information

SIGNAMAX a.s.
Seat: Palackeho trida 38, 612 00 Brno, CZ l Office: Vlarska 22, P. O. Box 214, 658 14 Brno, CZ
T:+420 533 338 854 l F:+420 533 338 883 l www.signamax.eu
8
1
3-6. QoS(Quality of Service) Configuration
The switch support four QoS queues per port with strict or weighted fair queuing
scheduling. There are 24 QoS Control Lists (QCL) for advance programmable QoS
classification, based on IEEE 802.1p, Ethertype, VID, IPv4/IPv6 DSCP and UDP/TCP ports
and ranges.
High flexibility in the classification of incoming frames to a QoS class. The QoS
classification looks for information up to Layer 4, including IPv4 and IPv6 DSCP, IPv4
TCP/UDP port numbers, and user priority of tagged frames. This QoS classification
mechanism is implemented in a QoS control list (QCL). The QoS class assigned to a frame is
used throughout the device for providing queuing, scheduling, and congestion control
guarantees to the frame according to what was configured for that specific QoS class.
The switch support advanced memory control mechanisms providing excellent
performance of all QoS classes under any traffic scenario, including jumbo frame. A super
priority queue with dedicated memory and strict highest priority in the arbitration. The ingress
super priority queue allows traffic recognized as CPU traffic to be received and queued for
transmission to the CPU even when all the QoS class queues are congested.
3-6-1. Ports
Function name:
Port QoS Configuration
Function description:
To configure each port QoS behavior. Four QoS queue per port with strict or weighted fair
queuing scheduling. There are 24 QoS Control Lists (QCL) for advance programmable QoS
classification, based on IEEE 802.1p, Ethertype, VID, IPv4/IPv6 DSCP and UDP/TCP ports and
ranges.
Fig. 3-34
Parameter description: