System information
SIGNAMAX a.s.
Seat: Palackeho trida 38, 612 00 Brno, CZ l Office: Vlarska 22, P. O. Box 214, 658 14 Brno, CZ
T:+420 533 338 854 l F:+420 533 338 883 l www.signamax.eu
288
set manual <YYYY/MM/DD> <hh:mm:ss>
Description:
To set up the current time manually.
Argument:
YYYY : Year (2000-2036) MM : Month (01-12)
DD : Day (01-31) hh : Hour (00-23)
mm : Minute (00-59) ss : Second (00-59)
Possible value:
YYYY : (2000-2036) MM : (01-12)
DD : (01-31) hh : (00-23)
mm : (00-59) ss : (00-59)
Example:
065-7851(time)# set manual 2004/12/23 16:18:00
set ntp
Syntax:
set ntp <ip> <timezone>
Description:
To set up the current time via NTP server.
Argument:
<ip>: ntp server ip address or domain name
<timezone>: time zone (GMT), range: -12 to +13
Possible value:
<timezone>: -12,-11…,0,1…,13
Example:
065-7851(time)# set ntp clock.via.net 8
Synchronizing...(1)
Synchronization success
show
Syntax:
show
Description:
To show the time configuration, including “Current Time”, “NTP Server”,” Timezone”,
” Daylight Saving”,” Daylight Saving Start” and “Daylight Saving End”
Argument:
None.
Possible value:
None.
Example:
065-7851(time)# show
Current Time : Thu Thu 14 15:04:03 2005
NTP Server : 209.81.9.7
Timezone : GMT+8:00
Day light Saving : 0 Hours
Day light Saving Start : Mth: 1 Day: 1 Hour: 0
Day light Saving End : Mth: 1 Day: 1 Hour: 0
065-7851(time)#