System information
SIGNAMAX a.s.
Seat: Palackeho trida 38, 612 00 Brno, CZ l Office: Vlarska 22, P. O. Box 214, 658 14 Brno, CZ
T:+420 533 338 854 l F:+420 533 338 883 l www.signamax.eu
266
8 Auto Disabled 9600 Restart salesdepartment
9 Auto Disabled 9600 Restart
10 Auto Disabled 9600 Restart
11 Auto Disabled 9600 Discard
set flow-control
Syntax
:
set flow-control <port-range> <enable|disable>
Description:
To set per-port flow control
Argument:
<port-range>: syntax 1,5-7, available from 1 to 24
Possible value:
<port-range>: 1 ~ 24
Example:
065-7851(port)# set flow-control 3-10
065-7851(port)# show config
1 Auto Disabled 9600 Doscard
2 Auto Disabled 9600 Discard
3 Auto Enabled 9600 Discard salesdepartment
4 Auto Enabled 9600 Discard salesdepartment
5 Auto Enabled 9600 Discard salesdepartment
6 Auto Enabled 9600 Restart salesdepartment
7 Auto Enabled 9600 Restart salesdepartment
8 Auto Enabled 9600 Restart salesdepartment
9 Auto Enabled 9600 Restart
10 Auto Enabled 9600 Restart
11 Auto Disabled 9600 Discard
12 Auto Disabled 9600 Discard
set max-frame
Syntax:
set max-frame <port-range> <value>
Description:
To set per-port maximum frame size
Argument:
<port range> syntax : 1,5-7, available from 1 to 24
<value> : Allowed value are 1518-9600 bytes.
Possible value:
<port range> syntax : 1 to 24
<value> : 1518-9600 bytes.
Example:
065-7851(port)# set max-frame 3-6 1518
065-7851(port)# show config
Speed/ Flow Maximum Excessiveommands
2 Auto Disabled 9600 Discard
3 Auto Enabled 1518 Discard salesdepartment
4 Auto Enabled 1518 Discard salesdepartment
5 Auto Enabled 1518 Discard salesdepartment
6 Auto Enabled 1518 Restart salesdepartment