System information

SIGNAMAX a.s.
Seat: Palackeho trida 38, 612 00 Brno, CZ l Office: Vlarska 22, P. O. Box 214, 658 14 Brno, CZ
T:+420 533 338 854 l F:+420 533 338 883 l www.signamax.eu
264
065-7851(policy)# add name rule2 ip 192.168.4.23-192.168.4.33 port 6-8 type s,t
action d
065-7851(policy)# show
1) Name : rule1 IP Range : 192.168.4.5-192.168.4.22
Action : Deny Access Type : HTTP TELENT SNMP
Port : 2 3 4 5
2) Name : rule2 IP Range : 192.168.4.23-192.168.4.33
Action : Deny Access Type : TELENT SNMP
Port : 6 7 8
065-7851(policy)# delete 2
065-7851(policy)# show
1) Name : rule1 IP Range : 192.168.4.5-192.168.4.22
Action : Deny Access Type : HTTP TELENT SNMP
Port : 2 3 4 5
065-7851(policy)#
show
Syntax
:
show
Description:
To show management policy list.
Argument:
none
Possible value:
none
Example:
065-7851(policy)# show
1) Name : rule1 IP Range : 192.168.4.5-192.168.4.22
Action : Deny Access Type : HTTP TELENT SNMP
Port : 2 3 4 5
2) Name : rule2 IP Range : 192.168.4.23-192.168.4.33
Action : Deny Access Type : TELENT SNMP
Port : 6 7 8
port
clear counter
Syntax:
clear counter
Description
:
To clear all ports’ counter (include simple and detail port counter) information.
Argument
:
None
Possible value:
None
Example: