System information
SIGNAMAX a.s.
Seat: Palackeho trida 38, 612 00 Brno, CZ l Office: Vlarska 22, P. O. Box 214, 658 14 Brno, CZ
T:+420 533 338 854 l F:+420 533 338 883 l www.signamax.eu
2
55
mstp
disable
Syntax:
disable
Description:
To disable mstp function.
Argument:
None
Possible value:
None
Example:
065-7851 (mstp)# disable
enable
Syntax:
enable
Description:
To enable mstp function.
Argument:
None
Possible value:
None
Example:
065-7851 (mstp)# enable
migrate-check
Syntax:
migrate-check <port-range>
Description:
To force the port to transmit RST BPDUs.
Argument
:
Usage: migrate-check <port range>
port range syntax: 1,5-7, available from 1 to 24
Possible value:
Usage: migrate-check <port range>
port range syntax: 1,5-7, available from 1 to 24
Example:
065-7851 (mstp)# migrate-check 1-2
set config
Syntax:
set config <Max Age><Forward Delay><Max Hops>
Description:
To set max age,forward delay,max hops.
Argument:
<Max Age> : available from 6 to 40. Recommended value is 20