2-1-4-1. Configuring the Management Agent of 065-7851 through the Serial RS-232 Port
To perform the configuration through RS-232 console port, the switch’s serial port must
be directly connected to a DCE device, for example, a PC, through RS-232 cable with DB-
9 connector. Next, run a terminal emulator with the default setting of the switch’s serial port.
With this, you can communicate with the switch.
In the switch, RS-232 interface only supports baud rate 115200 bps with 8 data bits, 1
stop bit, no parity check and no flow control.
To configure the switch, please follow the procedures below:
1. Find the RS-232 DB-9 cable with female DB-9 connector bundled. Normally, it just
uses pins 2, 3 and 7. See also Appendix B for more details on Null Modem Cable
Specifications.
2.
Attaches the DB-9 female cable connector to the male serial RS-232 DB-9
connector on the switch.
3. Attaches the other end of the serial RS-232 DB-9 cable to PC’s serial port,
running a terminal emulator supporting VT100/ANSI terminal with The switch’s
serial port default settings. For example, Windows98/2000/XP HyperTerminal
utility.
Note: The switch’s serial port default settings are listed as follows:
Baud rate 115200
Stop bits 1
Data bits 8
Parity N
Flow control none
4. When you complete the connection, then press <Enter> key. The login prompt will
be shown on the screen. The default username and password are shown as
below:
Username = admin Password = admin
065-7851 L2 Managed Switch
Default IP Setting:
IP address = 192.168.1.1
Subnet Mask = 255.255.255.0
Default Gateway = 192.168.1.254
Terminal or Terminal Emulato
r
Fig. 2-7
RS-232 cable
with female
DB-9 connector
at both ends
RS-232 DB-9 Connector