System information

SIGNAMAX a.s.
Seat: Palackeho trida 38, 612 00 Brno, CZ l Office: Vlarska 22, P. O. Box 214, 658 14 Brno, CZ
T:+420 533 338 854 l F:+420 533 338 883 l www.signamax.eu
218
set auth-server
Syntax:
set auth-server <ip-address> <udp-port> <secret-key>
Description:
To configure the settings related with 802.1X Radius Server.
Argument:
<ip-address> : the IP address of Radius Server
<udp-port> : the service port of Radius Server(Authorization port)
<secret-key> : set up the value of secret-key, and the length of secret-key is
from 1 to 31
Possible value:
<udp-port > : 1~65535, default is 1812
Example:
065-7851(802.1X)# set auth-server 192.168.1.115 1812 WinRadius
set suppTimeout
Syntax
:
set suppTimeout <port-range> <value>
Description
:
A timer used by the Backend Authentication state machine in order to determine timeout
conditions in the exchanges between the Authenticator and the Supplicant or Authentication
Server. The initial value of this timer is either suppTimeout or serverTimeout, as determined
by the operation of the Backend Authentication state machine.
Argument:
<port range> : syntax 1,5-7, available from 1 to 24
<value> : timer , range 1-65535
Possible value:
<port range> : 1 to 24
<value> : 1-65535, default is 30
Example:
065-7851(802.1X)# set suppTimeout 2 30
set txPeriod
Syntax:
set txPeriod <port-range> <value>
Description:
A timer used by the Authenticator PAE state machine to determine when an EAPOL PDU is to
be transmitted
Argument:
<port range> : syntax 1,5-7, available from 1 to 24
<value> : timer , range 1-65535
Possible value:
<port range> : 1 to 24
<value> : 1-65535, default is 30
Example:
065-7851(802.1X)# set txPeriod 2 30