System information

SIGNAMAX a.s.
Seat: Palackeho trida 38, 612 00 Brno, CZ l Office: Vlarska 22, P. O. Box 214, 658 14 Brno, CZ
T:+420 533 338 854 l F:+420 533 338 883 l www.signamax.eu
21
3
restore user
Syntax:
restore user
Description:
To restore the startup configuration as user defined configuration. If restoring default
successfully, the CLI would prompt if reboot immediately or not. If you press Y or y, the
system would reboot immediately; others would back to the CLI system. After restoring user-
defined configuration, all the changes in the startup configuration would be lost. After
rebooting, the entire startup configuration would replace as user defined one.
Argument:
None.
Possible value:
None.
Example:
065-7851# restore user
Restoring ...
Restore User Configuration Successfully
Press any key to reboot system.
save start
Syntax:
save start
Description:
To save the current configuration as the start one. When you enter this command, the CLI
would save your current configuration into the non-volatile FLASH. If you want the
configuration still works after rebooting, save the configuration using the command ‘save stat’.
Argument:
None.
Possible value:
None.
Example:
065-7851# save start
Saving start...
Save Successfully
065-7851#