System information

SIGNAMAX a.s.
Seat: Palackeho trida 38, 612 00 Brno, CZ l Office: Vlarska 22, P. O. Box 214, 658 14 Brno, CZ
T:+420 533 338 854 l F:+420 533 338 883 l www.signamax.eu
192
3-16. Alarm configuration
Function name:
Events Configuration
Function description:
The Trap Events Configuration function is used to enable the switch to send out the trap
information while pre-defined trap events occurred. The switch offers 24 different trap
events to users for switch management. The trap information can be sent out in three
ways, including email, mobile phone SMS (short message system) and trap. The
message will be sent while users tick () the trap event individually on the web page
shown as below.
Parameter description:
Trap: Cold Start, Warm Start, Link Down, Link Up, Authentication
Failure, User login, User logout
STP:
STP Topology Changed, STP Disabled, STP Enabled
LACP: LACP Disabled, LACP Enabled, LACP Member Added, LACP Port
Failure
GVRP: GVRP Disabled, GVRP Enabled
VLAN: VLAN Disabled, Port-based VLAN Enabled, Tag-based VLAN
Enabled, Metro-mode Vlan Enabled, Double-tag Vlan Enabled
Module Swap: Module Inserted, Module Removed, Dual Media Swapped
Events Confi
g
uration
Email/SMS Confi
g
uration
A
larm Confi
g
uration
Fig.3-61