System information
SIGNAMAX a.s.
Seat: Palackeho trida 38, 612 00 Brno, CZ l Office: Vlarska 22, P. O. Box 214, 658 14 Brno, CZ
T:+420 533 338 854 l F:+420 533 338 883 l www.signamax.eu
1
3
2-1-3-3. Switch Cascading in Topology
• Takes the Delay Time into Account
Theoretically, the switch partitions the collision domain for each port in switch
cascading that you may up-link the switches unlimitedly. In practice, the network extension
(cascading levels & overall diameter) must follow the constraint of the IEEE
802.3/802.3u/802.3z and other 802.1 series protocol specifications, in which the limitations
are the timing requirement from physical signals defined by 802.3 series specification of
Media Access Control (MAC) and PHY, and timer from some OSI layer 2 protocols such as
802.1d, 802.1q, LACP and so on.
The fiber, TP cables and devices’ bit-time delay (round trip) are as follows:
1000Base-X TP, Fiber 100Base-TX TP 100Base-FX Fiber
Round trip Delay: 4096
Round trip Delay: 512
Cat. 5 TP Wire: 11.12/m Cat. 5 TP Wire: 1.12/m Fiber Cable: 1.0/m
Fiber Cable : 10.10/m TP to fiber Converter: 56
Bit Time unit : 1ns (1sec./1000 Mega bit)
Bit Time unit: 0.01
μ
s (1sec./100 Mega bit)
Table 2-2
Sum up all elements’ bit-time delay and the overall bit-time delay of wires/devices must
be within Round Trip Delay (bit times) in a half-duplex network segment (collision domain).
For full-duplex operation, this will not be applied. You may use the TP-Fiber module to extend
the TP node distance over fiber optic and provide the long haul connection.
• Typical Network Topology in Deployment
A hierarchical network with minimum levels of switch may reduce the timing delay
between server and client station. Basically, with this approach, it will minimize the number of
switches in any one path; will lower the possibility of network loop and will improve network
efficiency. If more than two switches are connected in the same network, select one switch as
Level 1 switch and connect all other switches to it at Level 2. Server/Host is recommended to
connect to the Level 1 switch. This is general if no VLAN or other special requirements are
applied.