2-1-2. Installing Chassis to a 19-Inch Wiring Closet Rail
Caution: Allow a proper spacing and proper air ventilation for the cooling fan at both
sides of the chassis.
Wear a grounding device for electrostatic discharge.
Screw the mounting accessory to the front side of the switch (See Fig. 2-2).
Place the Chassis into the 19-inch wiring closet rail and locate it at the proper position.
Then, fix the Chassis by screwing it.
2-1-3. Cabling Requirements
To help ensure a successful installation and keep the network performance good,
please take a care on the cabling requirement. Cables with worse specification will render the
LAN to work poorly.
2-1-3-1. Cabling Requirements for TP Ports
For Fast Ethernet TP network connection
The grade of the cable must be Cat. 5 or Cat. 5e with a maximum length of 100
meters.
Gigabit Ethernet TP network connection
The grade of the cable must be Cat. 5 or Cat. 5e with a maximum length of 100
meters. Cat. 5e is recommended.
2-1-3-2. Cabling Requirements for 1000SX/LX SFP Module
It is more complex and comprehensive contrast to TP cabling in the fiber media.
Basically, there are two categories of fiber, multi mode (MM) and single mode (SM). The later
is categorized into several classes by the distance it supports. They are SX, LX, LHX, XD,
and ZX. From the viewpoint of connector type, there mainly are LC and BIDI LC.
Gigabit Fiber with multi-mode LC SFP module
Fig. 2-2