User`s guide
Signamax
065-7726SPOE / 065-7726SPOE-FP 24-Port 10/100BaseT/TX
PoE Managed Switch User Manual
Publication date: February 2010
Revision A1.0
74
Add Group:
Input the VLAN name, VID and then choose the member by ticking the check box
beside the port No. to create a new Tag-based VLAN. The parameter of Untag
stands for an egress rule of the port. If you tick the check box beside the port No.,
packets with this VID outgoing from this port will be untagged. Finally, press the
<Apply> button to have the setting taken effect.
Fig. 3-23
Delete Group:
Just press the <Delete> button to remove the selected group entry from the Tag-
based group table.
Fig. 3-24
Edit a group:
Just select a group entry and press the <Edit> button, then you can modify a
group’s description, member and untag settings.