User`s guide
Signamax
065-7726SPOE / 065-7726SPOE-FP 24-Port 10/100BaseT/TX
PoE Managed Switch User Manual
Publication date: February, 2010
Revision A1.0
61
Port No:
Port number.
Port On:
Show whether the port is supplying the power to the PD or not.
AC Disconnect Port Off:
Port is turned off due to the AC Disconnect function.
DC Disconnect Port Off:
Port is turned off due to the DC Disconnect function.
Overload Port Off:
The switch will stop supplying the power to the port due to the power required by the
PD that is linked to the port on the switch excesses the Class setting of the PD.
Short Circuit Port Off:
The switch will stop supplying the power to the port if it detects that the PD linked to
the port is short circuit.
Over Temp. Protection:
The port of the switch will be disabled due to fast transient rise in temperature to
240
o
C or slow rise in temperature to 200
o
C.
Power Management Port Off:
Due to total power required by all PDs linked to the switch excesses the power limit,
so the switch stops supplying the power to this port after referring to the information
of the priority.