User`s guide

Signamax
065-7726SPOE / 065-7726SPOE-FP 24-Port 10/100BaseT/TX
PoE Managed Switch User Manual
Publication date: February 2010
Revision A1.0
20
2-1-4-2. Configuring the Management Agent of the 065-7726SPOE and/or 065-7726SPOE-
FP through the Ethernet Port
There are three ways to configure and monitor the switch through the switch’s Ethernet
port. They are CLI, Web browser and SNMP manager. The user interface for the last one is
NMS dependent and does not cover here. We just introduce the first two types of management
interface.
Managing 065-7726SPOE and/or 065-7726SPOE-FP through an Ethernet Port
Before you communicate with the switch, you have to finish first the configuration
of the IP address or to know the IP address of the switch. Then,
follow the procedures listed below.
1. Set up a physical path between the configured the switch and a PC by a qualified UTP
Cat. 5 cable with RJ-45 connector.
Note: If PC directly connects to the switch, you have to setup the same subnet mask
between them. But, subnet mask may be different for the PC in the remote site. Please
refer to Fig. 2-9 about the switch’s default IP address information.
2. Run CLI or web browser and follow the menu. Please refer to Chapter 3 and Chapter 4.
065-7726SPOE
and/or 065-7726SPOE-FP
Default IP Setting:
IP = 192.168.1.1
Subnet Mask = 255.255.255.0
Default Gateway = 192.168.1.254
Assign a reasonable IP address,
For example:
IP = 192.168.1.100
Subnet Mask = 255.255.255.0
Default Gateway = 192.168.1.254
Fig. 2
-
9
Ethernet LAN