128
3-16. Bandwidth Management
Function name:
Ingress Bandwidth Setting
Function description:
Ingress Bandwidth Setting function is used to set up the limit of Ingress bandwidth for
each port.
Fig. 3-62
Parameter description:
Port No.:
Choose the port that you would like this function to work on it. Valid range of the port
is 1~26.
Rate:
Set up the limit of Ingress bandwidth for the port you choose. Incoming traffic will be
discarded if the rate exceeds the value you set up in Data Rate field. Pause frames
are also generated if flow control is enabled. The format of the packet limits to
unicast, broadcast and multicast. Valid value of Port 1~24 ranges from 66~102400,
and Port 25~26 ranges from 66~1024000 with the minimum unit of 1. Default value
of Port 1~24 is 102400 and Port 25~26 is 1024000.