23 SIGNAMAX LLC • www.signamax.eu
Cables
Ethernet Interface Cable
Ethernet interface cable of 065-7434 Signamax 24-Port 10/100 L3 switch
adopts 8-pin non-screen twisted pair. Silver plate 1 and 2 are the
sending ends; silver plate 3 and 6 are the sending ends.
The connection relation of RJ45 straight-through cable (type-5 twisted-
pair):
RJ45
Signal
Direction
RJ45
Description
Length
1
TX0+
>
1
Twisted
-
pair 1
2m
2
TX0
-
>
2
3
RX0+
<
3
Twisted
-
pair 2
6
RX0
-
<
6
4
48V
>
4
Twisted
-
pair 3
5
48V
>
5
7
0V
<—
7
Twisted
-
pair 4
8
0V
<
8
The connection relation of RJ45 crossover cable (type-5 twisted-pair):
RJ45 Signal Direction RJ45 Description Length
1 TX+ —> 3
Twisted-pair 1
2m
2 TX- —> 6
3 RX+ <— 1
Twisted-pair 2
6 RX- <— 2
4 48V —> 7
Twisted-pair 3
5
48V —>
8
7
0V
<— 4
Twisted-pair 4
8
0V
<