Installation guide

19 SIGNAMAX LLC • www.signamax.eu
Note
Installation suggestions:
When installing several devices on one cabinet, consider trying to install
heavier devices at or close to the bottom of the cabinet on the premise of
not affecting the whole cabling and layout. In this way, the gravity center
of the cabinet is lowered and the stability is improved.
When installing the device in the cabinet, it is recommended to reserve
1U space between the devices for dispersing the heat. Install the baffle
boards between the devices.
Connect Cables
This section describes the methods of connecting the cables on the
control board of the 065-7434 Signamax 24-Port 10/100 L3 Switch to the
network, including connecting the console port of the switch.
Connect Console Port of Switch
065-7434 Signamax 24-Port 10/100 L3 Switch provides one EIA/TIA-232
asynchronous serial console port, through which the user can adopt the
character terminal with RS-232 serial port (it is usually a PC) to configure
the switch.
For details of the connection and configuration, refer to the later chapter.
Configure the switch via the terminal as follows:
Step 1: Find a character terminal, which can be the terminal with RS-232
serial port or a PC. Usually, it is the latter.
Step 2: After confirming the switch or the character terminal is powered
off, connect the RS-232 serial port of the character terminal to the
console port of the switch by configuring cables.
Note
Pay attention to the interface ID during connection, so as to avoid
inserting into other interface.
Grounding Wire Connection