User`s manual
Signamax 065-1600 series Managed Media Converter
Publication date: October, 2005
Revision 1.0
73
Temperature Normal: E-mail, SMS and Trap
Issue alarm message via E-mail and SMS when the Signamax 065-1600
series’ case inside temperature recovered from (over 52
o
C or under 4
o
C)
to under (48
o
C and over 4
o
C). The default setting is shown as below:
E-mail : Send “Temperature Normal” alarm message by E-mail
when the case inside temperature recovered to normal
status. Default: Unchecked ()
SMS : Send “Temperature Normal” alarm message by Short
Message System when the case inside temperature
recovered to normal status. Default: Unchecked ()
Trap : Send Trap message to SNMP Trap Receiver when the
case inside temperature recovered to normal status.
Default: Checked ()
Case Opened: E-mail, SMS and Trap
Issue alarm message via E-mail and SMS when the Signamax 065-1600
series’ case was opened. The default setting is shown as below:
E-mail : Send “Case Opened” alarm message by E-mail when
case is opened. Default: Unchecked ()
SMS : Send “Case Opened” alarm message by Short Message
System when case is opened. Default: Unchecked ()
Trap : Send Trap message to SNMP Trap Receiver when case
is opened. Default: Checked ()
Case Closed: E-mail, SMS and Trap
Issue alarm message via E-mail and SMS when the Signamax 065-1600
series’ case was closed. The default setting is shown as below:
E-mail : Do not send “Case Closed” alarm message by E-mail
when case is closed. Default: Unchecked ()
SMS : Do not send “Case Closed” alarm message by Short
Message System when case is closed.
Default: Unchecked ()
Trap : Send Trap message to SNMP Trap Receiver when case
is closed. Default: Checked ()