3-4-9. Trap/Alarm Configuration
Function name:
Trap Events Configuration
Function description:
The Trap Events Configuration function is used to enable the Managed Media
Converter to send out the trap information while pre-defined trap events
occurred. Signamax 065-1600 series offers 16 different trap events to users
for converter management. The trap information can be sent out in three ways,
including e-mail, mobile phone SMS (short message system) and Trap. The
message will be sent while users tick () the trap event individually on the
web page shown as below.
Fig. 3-24
Parameter description:
STP Topology Changed: E-mail, SMS and Trap
E-mail : Send “STP Topology Changed” alarm message by E-mail
when the STP topology changed event happened.
Default: Unchecked ()
SMS
: Send “STP Topology Changed” alarm message by Short
Message System when the STP topology changed event
happened. Default: Unchecked ()
Trap : Send Trap message to SNMP Trap Receiver when the STP
topology changed event happened.
Default: Checked ()