User`s manual
Signamax 065-1600 series managed media converter
Publication date: October, 2005
Revision 1.0
42
3-4-1-3. System Time Setting
Signamax 065-1600 series provides manual and automatic ways to set the
system time via NTP. Manual setting is simple and you just input “Year”, “Month”,
“Day”, “Hour”, “Minute” and “Second” within the valid value range indicated in each
item. If you input an invalid value, for example, 61 in minute, the converter will
clamp the figure to 59.
NTP is a well-known protocol used to synchronize the clock of the Signamax
065-1600 series system time over a network. NTP, an internet draft standard
formalized in RFC 1305, has been adopted on the system is version 3 protocol.
Signamax 065-1600 series provides four built-in NTP server IP addresses resided
in the Internet and a user-defined NTP server IP address. The time zone is
Greenwich-centered which uses the expression form of GMT+/- xx hours.
Function name:
System Time Setting
Function description:
Set the system time by manual input or set it by syncing from Time servers.
The function also supports daylight saving for different area’s time adjustment.
Parameter description:
Manual:
This is the function to adjust the time manually. Filling the valid figures in
the fields of Year, Month, Day, Hour, Minute and Second respectively and
press <Apply> button, time is adjusted. The valid figures for the
parameter Year, Month, Day, Hour, Minute and Second are >=2000, 1-12,
1-31, 0-23, 0-59 and 0-59 respectively. Input the wrong figure and press
<Apply> button, the device will reject the time adjustment request. There
is no time zone setting in Manual mode.
Default: Year = 2000, Month = 1, Day = 1
Hour = 0, Minute = 0, Second = 0