User`s manual

Signamax 065-1600 series Managed Media Converter
Publication date: October, 2005
Revision 1.0
17
2-2-3-3. Installing Management Station through Signamax 065-1600 series
Fiber Port via Central Site Converter Chassis
Warning:
Both Signamax 065-1600 series converter and PC/station’s IP must be in a
same subnet, please assign a proper subnet mask.
To connect Signamax 065-1600 series fiber port to the central site
management station via fiber optic cable:
1. Locate the fiber network cable with the male fiber connector.
2. Attach the male fiber connector to the Managed Media Converter.
3. Attach the other end of cable to the Central Media Converter Chassis.
4. At central site:
- Install and connect a PC to TP port of the Central Media
Converter Chassis with Cat. 5 UTP network cable (or via a switch).
- Assign a reasonable public or private IP address in accordance with
each network site. Please refer to Fig. 2-10 about the Managed
Media converter default IP address information.
RC-2201/02
Default IP Setting:
IP = 192.168.1.1
Subnet Mask = 255.255.255.0
Default Gateway = 192.168.1.254
Network Management Station through RC-2201/02
Fiber Port via Central Site Converter Chassis
Assign a reasonable IP address,
for example:
IP = 192.168.1.2
Subnet Mask = 255.255.255.0
Default Gateway = 192.168.1.254
Fig. 2
-
10