User`s manual

Signamax 065-1600 series managed media converter
Publication date: October, 2005
Revision 1.0
222
rc2201PowerRecovered TRAP-TYPE
ENTERPRISE rc2201ProductId
DESCRIPTION
"Send this trap when the battery power of device has recovered."
::= 25
rc2201BatteryRecovered TRAP-TYPE
ENTERPRISE rc2201ProductId
DESCRIPTION
"Send this trap when the battery of device has recovered."
::= 26
rc2201BatteryExist TRAP-TYPE
ENTERPRISE rc2201ProductId
DESCRIPTION
"Send this trap when the battery of device has existed."
::= 27
rc2201StpStateDisabled TRAP-TYPE
ENTERPRISE rc2201ProductId
DESCRIPTION
"Send this trap when the operational state of STP is from enabled to
disabled. "
::= 100
rc2201StpStateEnabled TRAP-TYPE
ENTERPRISE rc2201ProductId
DESCRIPTION
"Send this trap when the operational state of STP is from disabled to
enabled. "
::= 101
rc2201StpTopologyChanged TRAP-TYPE
ENTERPRISE rc2201ProductId
VARIABLES { ifIndex }
DESCRIPTION
"Send this trap when RSTP determines a port should enter the
FORWARDING state
(a topology change occurs). The OID value is the ifIndex of the port that
produces the topology change"
::= 102
rc2201LacpStateDisabled TRAP-TYPE
ENTERPRISE rc2201ProductId
VARIABLES { lacpGroupId }
DESCRIPTION
"Send this trap when the operational state of LACP is from enabled to
disabled.
The OID value means the enabled Group ID. "
::= 120