User`s manual

Signamax 065-1600 series Managed Media Converter
Publication date: October, 2005
Revision 1.0
219
"The Fan Number."
::= { rc2201TrapEntry 6 }
bandwidth OBJECT-TYPE
SYNTAX DisplayString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The bandwidth of some port."
::= { rc2201TrapEntry 7 }
rc2201TemperatureOver TRAP-TYPE
ENTERPRISE rc2201ProductId
VARIABLES { temperature }
DESCRIPTION
"Send this trap when the temperature of the power is over 55 Celsius
degree.
The OID value means the temperature of the system. "
::= 1
rc2201TemperatureNormal TRAP-TYPE
ENTERPRISE rc2201ProductId
VARIABLES { temperature }
DESCRIPTION
"Send this trap when the temperature of the power is under 53 Celsius
degree from a
previous RC2201TemperatureOver Status or the temperature is upper 6
Celsius degree
from the previous RC2201TemperatureUnder Status. The OID value means
the temperature
of the system. "
::= 2
rc2201FanAbnormal TRAP-TYPE
ENTERPRISE rc2201ProductId
VARIABLES { fanNo, fanRPM }
DESCRIPTION
"Send this trap when the RPM of Fan is under 2800. The OID value
means the RPM of Fan
and the fan number."
::= 3
rc2201FanNormal TRAP-TYPE
ENTERPRISE rc2201ProductId
VARIABLES { fanNo, fanRPM }
DESCRIPTION
"Send this trap when the RPM of Fan is over 2800 from a previous
RC2201FanDown Status.
The OID value means the RPM of fan and the fan number. "
::= 4
rc2201VdcOver TRAP-TYPE