User`s manual

Signamax 065-1600 series managed media converter
Publication date: October, 2005
Revision 1.0
208
rc2201MaxBridgeTransmitDelayBound OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
-- @@ACTION popular_func
DESCRIPTION
"Get/Set the Maximum Bridge Transmit Delay Bnd.
value range (0|1|2|3)
0 - 1 sec,
1 - 2 secs,
2 - 4 secs,
3 - Off"
::= { rc2201PopularFuncMIB 14}
rc2201MaxDelayTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
-- @@ACTION popular_func
DESCRIPTION
"Get/Set the Maximum Delay Bound.
We must enable the max bridge transmit delay bound before
enabling the max delay time.
value range (0-255)
0 - disable delay bound
1 - delay 1 ms,
2 - delay 2 ms,
3 - delay 3 ms,
... and so on."
::= { rc2201PopularFuncMIB 15}
rc2201PowerDownSetting OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
-- @@ACTION popular_func
DESCRIPTION
"Get/Set the Power Down automatically when the fan stopped,
and temperature is over 60 degrees"
::= { rc2201PopularFuncMIB 16 }
-- Auto Ping Function
rc2201AutoPingMIB OBJECT IDENTIFIER ::= { rc2201Produces 5 }
rc2201AutoPingInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
-- @@ACTION AutoPing
DESCRIPTION
"Get/Set the auto ping time interval. (mins).