User`s manual

Signamax 065-1600 series managed media converter
Publication date: October, 2005
Revision 1.0
198
STATUS mandatory
-- @@ACTION sys_mib
DESCRIPTION
"UART test.
range (0|1)
1 - pass
0 - failure "
::= { rc2201SystemMIB 5 }
rc2201DramTest OBJECT-TYPE
SYNTAX INTEGER(0|1)
ACCESS read-only
STATUS mandatory
-- @@ACTION sys_mib
DESCRIPTION
"DRAM read/write test.
range (0|1)
1 - pass
0 - failure "
::= { rc2201SystemMIB 6 }
rc2201FlashChecksumTest OBJECT-TYPE
SYNTAX INTEGER(0|1)
ACCESS read-only
STATUS mandatory
-- @@ACTION sys_mib
DESCRIPTION
"Flash memory read test.
range (0|1)
1 - pass
0 - failure "
::= { rc2201SystemMIB 7 }
rc2201InternalLoopbackTest OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
-- @@ACTION sys_mib
DESCRIPTION
"Do the internal loopback test (from port 1 to port 2). "
::= { rc2201SystemMIB 8 }
rc2201ExternalLoopbackTest OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
-- @@ACTION sys_mib
DESCRIPTION
"Do the external loopback test (from port 1 to port 2). "
::= { rc2201SystemMIB 9 }
------------------------------------------------------------------------------------