User`s manual

Signamax 065-1600 series Managed Media Converter
Publication date: October, 2005
Revision 1.0
197
rc2201Produces OBJECT IDENTIFIER ::= { rc2201ProductId 1 }
rc2201SystemMIB OBJECT IDENTIFIER ::= { rc2201Produces
1 }
rc2201Temperature OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
-- @@ACTION sys_mib
DESCRIPTION
"Read the value from the temperature sensor. It is a numerical
series
of 5. There is a difference of 0.5 Celsius degree between a level
and
its next one."
::= { rc2201SystemMIB 1 }
rc2201FanRPM OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
-- @@ACTION sys_mib
DESCRIPTION
"Return an approximate RPM of the fan1 on the back panel. The
value less
than or equal to 4200 represents that the fan is operational, else
breakdown."
::= { rc2201SystemMIB 2 }
rc2201DevicePort OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
-- @@ACTION sys_mib
DESCRIPTION
"Get the quantity of ports that this system owns now."
::= { rc2201SystemMIB 3 }
rc2201CaseIntrusion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
-- @@ACTION sys_mib
DESCRIPTION
"Detect the Case is opened or closed."
::= { rc2201SystemMIB 4 }
rc2201UARTTest OBJECT-TYPE
SYNTAX INTEGER(0|1)
ACCESS read-only