User`s manual
Signamax 065-1600 series Managed Media Converter
Publication date: October, 2005
Revision 1.0
193
smtpPasswd OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
-- @@ACTION comm_alarm_smtp
DESCRIPTION
"The password for SMTP server."
::= { alarm 3 }
noOfEmailUsers OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
-- @@ACTION comm_alarm_smtp
DESCRIPTION
"The number of the Email Users that you want to send the alarm
notification."
::= { alarm 4 }
emailUserTable OBJECT-TYPE
SYNTAX SEQUENCE OF EmailUserEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of EmailUserEntry. The number of entries is given by the
value of NoOfEmailUsers."
::= { alarm 5 }
EmailUserEntry ::=
SEQUENCE {
emailUserIndex INTEGER,
emailAddress DisplayString
}
emailUserEntry OBJECT-TYPE
SYNTAX EmailUserEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry includes the user index and Email Address."
INDEX { emailUserIndex }
::= { emailUserTable 1 }
emailUserIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
-- @@ACTION comm_alarm_smtpEntry
DESCRIPTION
"The User Index that you want to send alarming E-mail."
::= { emailUserEntry 1 }