STATUS mandatory
-- @@ACTION comm_config_exportEntry
DESCRIPTION
"the index of the flash sector.
range (1|2)
0x01 user0 (working)
0x02 user1"
::= { configurationExportEntry 1 }
configurationExportFileName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
-- @@ACTION comm_config_exportEntry
DESCRIPTION
"The importing configuration file name. Include the path.
The default value is user0, user1...etc. Depending on the flash
sector index."
::= { configurationExportEntry 2 }
doExportConfiguration OBJECT-TYPE
SYNTAX INTEGER(0|1)
ACCESS read-write
STATUS mandatory
-- @@ACTION comm_config_exportEntry
DESCRIPTION
"This is a trigger to do export configuration if you set to 1 to the OID.
range (0|1)
0 - no effect
1 - do kernel image updrade."
::= { configurationExportEntry 3 }
----------------------------------------------------------------------------------------
alarm OBJECT IDENTIFIER ::= { CommonMIB 5 }
smtpServer OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
-- @@ACTION comm_alarm_smtp
DESCRIPTION
"The SMTP Email Server IP Address."
::= { alarm 1 }
smtpUsername OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
-- @@ACTION comm_alarm_smtp
DESCRIPTION
"The username for SMTP server."
::= { alarm 2 }