User`s manual
Signamax 065-1600 series Managed Media Converter
Publication date: October, 2005
Revision 1.0
13
RC-2201/02
Default IP Setting:
IP address = 192.168.1.1
Subnet Mask = 255.255.255.0
Default Gateway = 192.168.1.254
2-2-3-1. Installing Management Station through the Signamax 065-1600 series’
RS-232 Port
The serial port cable is attached directly to a DCE device through an RS-232
cable for console management.
To connect the Managed Media Converter to the console user interface:
1. Locate the correct DB-9 serial port RS-232 cable with female DB-9
connector. Please refer to Appendix B for more details on Null Modem
Cable Specifications.
2. Attach the DB-9 female cable connector to the male DB-9 serial port
connector on the Managed Media Converter.
3. Attach the other end of the DB-9 serial port cable to an ASCII terminal
emulator. For example, Windows98/2000/XP HyperTerminal utility.
Signamax 065-1600 series converter uses the following serial port
parameter values:
Baud rate 57600
Stop bits 1
Data bits 8
Parity N
Flow control none
4. When the terminal emulator connected to Signamax 065-1600 series,
then press <Enter> key, the login prompt will be shown on the screen.
The default username and password are shown as below:
Username = admin
Password = admin
Terminal or Terminal Emulator
5V DC
Jack
RS-232
RS-232 cable with female
DB-9 connector at both ends
Fig. 2-6