User`s manual

Signamax 065-1600 series managed media converter
Publication date: October, 2005
Revision 1.0
124
4-4-1-7. Power Down Setting
Function name:
Power Down Setting
Function description:
This design is concerning for system safety. This function will detect two things:
the temperature if over 60
o
C, the cooling fan if failed. If these two conditions
happened at the same time and the “Power Down Setting” was enabled, the
Signamax 065-1600 series will power down automatically.
Parameter description:
Disable:
If this function is disabled, the Signamax 065-1600 series will keep
working regardless of the temperature was over 60
o
C and the cooling fan
failed at the same time.
Enable:
In this status, the Signamax 065-1600 series will power down
automatically while the temperature was over 60
o
C and the cooling fan
failed at the same time.
Default: Enable
Fig. 4-20