User`s manual

Signamax 065-1600 series Managed Media Converter
Publication date: October, 2005
Revision 1.0
115
4-4-1-3. IP Configuration
IP configuration is one of the most important configurations in Signamax 065-
1600 series. Without the proper setting, network manager will not be able to see the
device. Signamax 065-1600 series supports both manual IP address setting and
automatic IP address setting via DHCP server. When IP address is changed, you
must reboot the converter to have the setting taken effect and use the new IP for
web management and telnet console management.
Function name: IP Configuration
Function description:
Set IP address, subnet mask, default gateway and DNS for Signamax 065-
1600 series.
Fig. 4-12
Parameter description:
DHCP:
Signamax 065-1600 series supports DHCP client used to get an IP
address automatically if you set this function “Enable”. Signamax 065-
1600 series will find the DHCP server existed in the network to get an IP
address. If DHCP server is down or does not exist and DHCP in
Signamax 065-1600 series is enabled, then Signamax 065-1600 series
will count down 60 seconds and use its fixed IP set last time. If this
function is set “Disable”, you have to input IP address manually. For
more details about IP address, please see the 2-2-4 section “IP Address
Assignment” in this manual.
Default: Disable
IP Address:
Users can configure the IP settings and fill in new values if users set the
DHCP function “Disable”. Then, move the cursor to <Save> and press
<Enter> key to update it. Default: 192.168.1.1