User Manual

10/11/12 Page 2 of 12
SignalFire Telemetry Rev 1.2
Specifications
Enclosure Size: 3.5” tall x 5.0” wide x 5.0” deep
Power Source: Internal IS Lithium battery pack. SignalFire Part Number:
810-0008-02
External Solar battery system. SignalFire Part Number:
SENTINEL-SOLAR
Other external power supply meeting the power entity parameters
from the control drawing.
Temperature Range: -40ºC to +60 ºC
Radio Frequency: 902-928MHz ISM Band, FHSS radio, internal antenna
Compliance: Certified for use in Class I, Division 1 groups C and D. EXi [EXi]
FCC/IC Certified.
WARNING: Use of this equipment in a manner not specified
by the manufacturer may impair the protection provided by the
equipment.
WARING: The use of any parts not supplied by the
manufacturer violates the safety rating of the equipment
The associated apparatus provides intrinsically safe outputs
L'appareil associé fournit des sorties à sécurité intrinsèque
Refer to control drawing 960-0026-01 for requirements when used in a
Class I Division 1 area.