User Manual

10/15/2012 Page 10 of 12
SignalFire Telemetry
Internal Lithium Battery Replacement
Battery Packs can be changed in with the node in place.
1. Open the cover from the enclosure.
2. Unplug the battery from the PCB, by depressing the locking clip on the connector.
3. Loosen the screw holding the battery door and slide the old battery out.
4. Slide in the new battery pack and tighten the battery door screw.
5. Connect the battery to the main PCB battery connector.
6. Install the enclosure cover.
WARNING: Use of any battery other than the SignalFire
part number 810-0008-02 will impair the protection provided by
the equipment.
WARNING: If the internal battery is installed the external
solar battery system or other power source may not be connected!
Cleaning Instructions
The outside of the enclosure may be cleaned with water and a mild soap with a damp
cloth as needed. High pressure washing is not recommended.
WARNING: Electrostatic Discharge Hazard! Care must be
taken to avoid the potential of creating a change on the enclosure
or antenna. Do not wipe with a dry cloth. Do not brush against
the enclosure with clothing or gloves.