User's Manual

12
Internal Lithium Battery Replacement
Battery Packs can be changed with the node in place.
1 Open the cover.
2 Slide the power switch to the off position
3 Unplug the battery from the PCB, by depressing the locking clip on the connector.
4 Remove the battery from the clip and replace with new battery.
5 Connect the battery to the main PCB battery connector.
6 Slide the power switch to the on position.
7 Close and snap shut the enclosure cover.
WARNING: Use of any battery other than the SignalFire part number 810-0030-01
(1BIS) will impair the protection provided by the equipment.
AVERTISSEMENT: La sécurité intrinsèque et la protection du produit seront
compromis par l’utilisation de batteries autres que celle fournie par SignalFire ayant
comme numéro de pièce 810-0030-01(1BIS).
Coin Cell Battery Replacement
The coin cell is used to backup the real time clock in the event that the main battery pack is
unplugged. The battery is a CR2032 coin cell battery
WARNING: Use of any battery other than a Panasonic CR2032 coin cell battery will
impair the protection provided by the equipment.
AVERTISSEMENT: La sécurité intrinsèque et la protection du produit seront
compromis par l’utilisation de batteries autres que celle fournie par SignalFire ayant
comme numéro de pièce Panasonic CR2032.
SignalFire Telemetry
Rev 2.4