Specifications

Smeal Pumper Demo # 4276
Page 50 of 58
All electrical terminals that are not grounded shall have a protective covers or be in an enclosure.
TAIL LIGHTS
There shall be a Weldon model 4694 tail light assembly installed on each side of the rear of the
apparatus. Each tail light assembly shall include one (1) LED red stop/tail light, one (1) LED amber turn
light and one (1) LED clear back up light. The lights shall be mounted in a cast housing one per each side
of the apparatus. The remaining slot shall be filled with a warning light specified in the warning light
section.
MIDSHIP TURN SIGNALS
There shall be two (2) Truck-Lite model 21 LED midship auxiliary/turn signal lights installed. One (1) light
shall be located in the rub rail on each side of the body.
BODY GROUND LIGHTING
There shall be four (4) Grote White 4" round, LED lights model 61E41 installed beneath the apparatus in
areas where personnel may be expected to climb on and off of the apparatus. The lights shall illuminate
the ground within 30" of the apparatus to provide visibility of any obstructions or hazards. These areas
shall include, but shall not be limited to, side running boards and the rear step area.
There shall be four (4) aluminum ground light brackets provided to position each ground light so as to
illuminate the ground within 30" of the apparatus.
CLEARANCE LIGHTS
Grote model 65282 red LED clearance lights shall be installed in the rear tailboard as necessary to be in
full compliance with applicable ICC and DOT codes and regulations. Clearance reflectors shall be placed
on the apparatus to be in full compliance with applicable ICC and DOT codes and regulations.
REAR WORK LIGHT SWITCH
A switch shall be installed above the tail light bezel on the left side of the rear of the apparatus. The
switch shall be wired to the backup lights to provide additional work lighting. The rear work light circuit
shall be deactivated when the park brake is disengaged. In addition to the lights being activated by the
above switch, the lights shall also come on when the transmission is placed in reverse.
GENERATOR
There shall be a Harrison, model 8.0MCR-16R hydraulic driven generator installed on the apparatus. The
continuous duty rating of the generator shall be 8,000 watts, 33/66 amps, 120/240VAC volts. Current
frequency shall be stable at 60 hertz.
The system shall be designed and assembled by a company with no less than 10 years experience in the
manufacture of hydraulic driven generators. The system shall be tested prior to shipping and shall be
accompanied with a test report. The generator shall be tested at various loads from no load to full load to
ensure reliable power delivery at various loads.