Specifications

Smeal Pumper Demo # 4276
Page 34 of 58
CROSSLAY CONFIGURATION
There shall be two (2) 1-1/2" crosslay pre-connects located above the pump module. Class1 high-
pressure flex hose with stainless steel couplings shall be used in the plumbing.
A Trident 90º swivel elbow shall be utilized to keep the hose from kinking when pulled from either side of
the apparatus. The swivel for each crosslay shall be located outboard for ease of making connections
while changing hose.
The pre-connect hose beds shall be sized to accommodate the following hose load:
There shall be a heavy duty 22 oz. hypalon vinyl coated nylon cover located over the top and on each
end of the pre-connected crosslays. The top of the cover shall be connected to the top-forward portion of
the crosslays through a C-Rail channel and shall attach on the top-rear portion using velcro. The bottom
of the end covers shall be attached to the pump module utilizing hooks and bungee cord.
The color of the vinyl restraint shall be red.
Stainless steel rollers shall be provided at each end of the crosslay hose bed to facilitate deployment of
hose. Vertical rollers shall be installed on each side of the hose bed opening, and a horizontal roller shall
be installed under the opening.
The floor of the crosslay shall be slotted sufficiently for drainage.
The 1-1/2" crosslay pre-connect shall have a capacity of 200' of 1-3/4" double jacket fire hose.
The crosslay pre-connect shall be capable of holding the hose in a single stack.
The 1-1/2" crosslay pre-connect shall have a capacity of 200' of 1-3/4" double jacket fire hose.
The crosslay pre-connect shall be capable of holding the hose in a single stack.
The interior of the crosslay hose bed shall be painted the primary body color.
There shall be one (1) divider in the crosslay area. The divider shall be fabricated of 3/16" aluminum and
be mounted in a channel on each end for adjustability.
The crosslay dividers shall have maintenance free abraded finish.
RIGHT SIDE PUMP ACCESS PANEL
There shall be a tread plate door above the right hand side pump panel to allow access to the pump
compartment. The vertically hinged panel shall be of the single pan design and shall be positively latched
in the closed position utilizing a push button latch. A gas strut shall be provided on the door. An aluminum
sill protector shall be installed on the bottom of the door opening to protect the paint from chipping and
scratching. The door shall be wired into the door open warning light circuit.
AIR HORN BUTTON