pump and plumbing access without the need to use hand tools. Any electrical equipment that may be
installed shall be equipped with connectors so they may be easily separated from the opening created
when the below described front access panel is removed.
PANEL SURFACES
The control panel, instrument panel, and right side pump panel shall be coated with black Line-X® for
maximum resistance to abrasion and to minimize glare. The material shall be capable of withstanding the
effects of extreme temperatures and weather.
PUMP PANEL LIGHTS
The pump operator's control panel and the right side pump panel shall each be illuminated by On-Scene
LED Night Axe lighting. The pump panel lights shall become energized upon setting the parking brake so
the gauge information provided may be consulted at any time the apparatus is parked. A stainless steel
shield shall be installed over the pump panel lights to further protect them from the elements and to act as
a reflector for additional illumination.
MASTER PUMP GAUGES
The pump vacuum and pressure gauges shall be supplied by Thuemling. Each gauge shall be fully filled
with pulse and vibration dampening Interlube to insure proper operations to minus 40 degrees and to
reduce lens condensation. The gauge shall read -30-0-400 PSI and shall be a minimum of 4-1/2" in
diameter.
PRESSURE AND VACUUM TEST PORT
There shall be a Class1 model 121384 pressure and vacuum test port provided on the pump panel.
ENGINE COOLER CONTROL VALVE
There shall be a Class1 model 38BV engine cooling control valve provided on the pump panel.
PUMP COOLER CONTROL VALVE
There shall be a Class1 model 38BV pump cooling control valve provided on the pump panel.
LEFT SIDE RUNNING BOARD
A modular bolt-on running board shall be installed on the side of the pump module. The running board
shall be constructed of anti-slip tread plate. The outside edge of the running board shall be flush with the
rub rail that is installed on the body to maintain a uniform appearance. The running board shall be
installed with sufficient support to form a sturdy, non-deflecting step area for personnel.
RIGHT SIDE RUNNING BOARD
A modular bolt-on running board shall be installed on the side of the pump module. The running board
shall be constructed of anti-slip tread plate. The outside edge of the running board shall be flush with the
rub rail that is installed on the body to maintain a uniform appearance. The running board shall be
installed with sufficient support to form a sturdy, non-deflecting step area for personnel.