RD0169 (A) CAF730 & SS730 OWNER’S MANUAL Page 13 of 28
5.8.2 SS730 Connections
There are three Neutrik NL4MP and one NL8MP connectors on the rear of each SS730. The
connectors mate, respectively, with Neutrik NL4FC and NL8FC in-line cable connectors.
SUB INPUT/OUTPUT NL4MP (each of two)
PIN 1- SS730 SUB 1-
PIN 1+ SS730 SUB 1+
PIN 2- SS730 SUB 2-
PIN 2+ SS730 SUB 2+
1. Use as the input to the SS730.
2. Use the second connector to loop SUB signals to additional SS730s.
5.8.3 SS730 System Input Connections
The NL8MP connector on the SS730s can be used as the input for an entire array. Using the
SS730 SYSTEM INPUT on one SS730, an NL8 cable carries all amplified signals from the array’s
amplifiers to this SS730. Using NL4 cabling from this SS730, you can loop up to eight CAF730s
and three additional SS730s. With the maximum combination, the nominal load for each of the
four amplified signals is 2 ohms.
SYSTEM INPUT NL8MP
PIN 1- SS730 SUB 1-
PIN 1+ SS730 SUB 1+
PIN 2- SS730 SUB 2-
PIN 2+ SS730 SUB 2+
PIN 3- CAF730 LF-
PIN 3+CAF730 LF+
PIN 4- CAF730 MF/HF-
PIN 4+ CAF730 MF/HF+
1. Connect the four different amplified signals needed to power a complete array of CAF730s and
SS730s to the SYSTEM INPUT.
2. Use the CAF730 OUTPUT to loop the LF and MF/HF signals to the CAF730s using NL4 cabling.
3. Use the SUB INPUT/OUTPUT to loop the Sub signals to the next SS730 using NL4 cabling.
4. Daisy-chain additional SS730s in a similar fashion.
CAF730 OUTPUT NL4MP
PIN 1- CAF730 LF-
PIN 1+ CAF730 LF+
PIN 2- CAF730 MF/HF-
PIN 2+ CAF730 MF/HF+
1. Connect to a CAF730 INPUT using NL4 cabling.
SS730 INPUT/OUTPUT 2x NL4MP
PIN 1- SS730 SUB 1-
PIN 1+ SS730 SUB 1+
PIN 2- SS730 SUB 2-
PIN 2+ SS730 SUB 2+
1. Connect to an SS730 INPUT using NL4 cabling.
CAF730